摘要:

基于射频信号处理的血管内超声弹性成像技术对于动脉粥样硬化易损斑块的识别具有重要意义。为验证超声弹性重建算法的准确性,设计了一种血管内超声射频信号采集系统,系统利用线同步信号为触发源,同步采集超声射频信号、心电和血压信号;引入基于单片机的控制模块,解决多块采集卡同步和超声射频信号帧间旋转不一致性矫正问题;将采集卡和控制模块等集成到同一控制平台下,实现各硬件块之间的协同工作;利用ini配置文件和MATLAB计算引擎调用技术,简化采集卡配置过程,实现采集结果的可视化。

Intravascular ultrasound elastography ( IVUSE ) based on radio frequency signal processing is proved to be significant in the identification of the vulnerability of atherosclerotic plaque. In order to test the validity of elasticity reconstruction algorithm, a data acquisition system was designed. Triggered by the line sync signal, this system acquired the radio frequency signal, ECG, blood pressure signal synchronously. On purpose of adjusting frame to frame rotational nonuniformity, a control module based on MCU was introduced. Aiming at simplifying data acquisition process, the system put all hardware under central control. With the help of ini file and MATLAB engine technique, the system both simplifyied the hardware configure process, and effectively showed the acquisition results.

参考文献:

[1]Falk E, Shah P, Fuster V.  Coronary plaque disruption.  Circulation,1995, 92: 657– 671.
[2]Fuster V, Stein B, Ambrose J, et al. Atherosclerotic plaque rupture and thrombosis: evolving concepts. Circulation, 1990, 82: 47-59.
[3]de Korte CL, Cespedes EI, van der Steen AFW, et al. Intravascular elasticity imaging using ultrasound: feasibility studies in phantoms. Ultrasound Med Biol, 1997, 23:  735–746 .
[4]de Korte CL, Woutman , Anton FW. van der Steen AFW. Vascular tissue characterization with IVUS elastography. Ultrasonics, 2000, 38: 387-390.
[5]de Korte CL, Gerard Pasterkamp, van der Steen HAW,et al. Characterization of Plaque Components With Intravascular Ultrasound Elastography in Human Femoral and Coronary Arteries In Vitro. Circulation, 2000 , 102: 617-623.
[6]朱新建,邵金华,刘科,等. 血管内超声弹性成像研究进展. 国际生物医学工程学杂志,2009, 32(1): 27-30.
[7]Maurice RL , Fromageau J, Brusseau E, et al. On the potential of the lagrangian estimator for endovascular ultrasound elastography:in vivo human coronary artery study. Ultrasound in Med & Biol , 2007 , 33(8) : 1199-1205.
[8]Saijo Y, Tanaka A, Iwamoto T, et al. Intravascular twodimensional tissue strain imaging. Ultrasonics, 2006,  44 : 147 – 151 .
[9]孙晓云,郭立炜,孙会琴. 基于Labwindows/CVI的虚拟仪器设计与应用. 北京:电子工业出版社, 2005.