设为首页 |  加入收藏
首页首页 期刊简介 消息通知 编委会 电子期刊 投稿须知 广告合作 联系我们
基于射频信号强度的胃肠道内微系统位置跟踪方法研究

Position Telemetering Based on Radio Frequency Signal Strength for MicroGastrointestinal Endoscope

作者: 刘勇  王文兴  颜国正 
单位:上海交通大学电子信息与电气工程学院(上海200240)
关键词: 定位;胃肠道内微系统;射频信号强度;算法 
分类号:
出版年·卷·期(页码):2010·29·4(353-359)
摘要:

为了解决对诸如胶囊内窥镜等胃肠道内微系统的实时位置跟踪问题,本文研究了基于射频信号强度对胃肠道内微系统进行定位的方法和系统。该系统在人体体外布置射频接收模块阵列,由采集到的射频信号强度的差异,对胃肠道内微系统进行跟踪定位。文中介绍了定位系统的具体实现,并搭建了初步的实验平台。实验结果表明,该跟踪方法具有一定的定位精度,能在一定范围内有效地跟踪目标物的位置。
 

In order to determine a position of microgastrointestinal endoscope, such as an implantable microcapsule, in gastrointestinal track, this paper develops a locating system based on radio frequency(RF) signal strength.In this system the array of RF sensors was located over the abdomen of human body, and these RF sensors obtained the radio frequency signal strength (RSS) by RF communication with the microgastrointestinal endoscope. Based on the localization model, the position of microgastrointestinal endoscope could be calculated from the difference of the RSSI caught by the array of the RF sensors. The realization of the localization system and the basic experiment device to validate this system were introduced. The experiments showed the localization system could be effective to tract the position of the target in some cases.
 

参考文献:

[1]周润景,郝整清.生物遥测的现状与发展.中国医疗器械志,2002,26 (3):212-214.
[2]Swain P,Iddan G, Mernn G.A wireless capsule endoscopy of the smallbowel development,testing and first human trials.Proceedings of SHE,2001,4158:19-23.
[3]朱玫, 王荣福. 放射性核素胃排空显像. 国外医学放射医学核医学分册, 2000, 4:23-25.
[4]Weitschies W, Cordini D, Karaus M, et al. Magnetic marker monitoring of esophageal, gastric and duodenal transit of nondisintegrating capsules.Pharmazie, 1999, 54(6):426-430.
[5]Wang XN, Meng MQH,Hu C. A Localization Method Using 3-axis Magnetic Sensors for Tracking of Capsule Endoscope. New York, SA:Proceedings of the 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society,2006: 2522-2525.
[6]Wu XD, Peng CL, Hou WS, et al. 3-D magnetic sensor module for locating and tracking MEMS swallowable capsule based on scalar form of  agnetic dipole model. Chinese journal of biomedical engineering, 2007, 16(2) :79-86.
[7]Jacob H, Levy D, Shreiber R, et al. Localization of the given M2A ingestible capsule in the given diagnostic imaging system. Gastrointestinal Endoscopy, 2002, 55(5): AB135.
[8]Arshak K,Adepoju FA. Method for Estimating the Geometric Position of a Wireless Telemetry Capsule in RealTime.Wireless Technologies, 2007 European Conference, 2007: 193-196.
[9]Shah T,Aziz SM,Vaithianathan T.Development of a Tracking Algorithm for an InVivo RF Capsule Prototype.Electrical and Computer Engineering, 2006. ICECE′06. International Conference, 2006: 173-176.
[10]Xu Huang. Antenna Polarization as Complementarities on RSSI Based Location Identification.Wireless Pervasive Computing.ISWPC 2009. 4th International Symposium, 2009:1-5.
[11]Arshak K, Adepoju F.A Model for Estimating the RealTime Positions of a moving Object in Wireless Telemetry Applications using RF Sensors.Sensors Applications Symposium. SAS ′07. IEEE,2007:1-6.
[12]Xiao Jizhong. Preprocessing technique to signal strength data of wireless sensor network for realtime distance estimation.Robotics and Automation. CabreraMora:ICRA 2008. IEEE International Conference, 2008:1537-1542.
 

服务与反馈:
文章下载】【加入收藏
提示:您还未登录,请登录!点此登录
 
友情链接  
地址:北京安定门外安贞医院内北京生物医学工程编辑部
电话:010-64456508  传真:010-64456661
电子邮箱:llbl910219@126.com