设为首页 |  加入收藏
首页首页 期刊简介 消息通知 编委会 电子期刊 投稿须知 广告合作 联系我们
Tween_20_对联吡啶钌电化学发光的增敏作用

Sensitization of Tween 20 on Ru(bpy)2+3 electrochemiluminescence

作者: 李志英  王捷  许喜林  陈健  刘仲明 
单位:广州军区广州总医院医学实验科(广州510010)
关键词: Ru(bpy)2+3;电化学发光;Tween  20;增敏效应 
分类号:
出版年·卷·期(页码):2012·31·4(402-406)
摘要:

目的为进一步提高联吡啶钌电化学发光检测的灵敏度,研究了非离子表面活性剂Tween 20对联吡啶钌电化学发光的增敏作用。方法 对Tween 20的浓度进行优化后,在最佳添加浓度0.1%的条件下,测试联吡啶钌的灵敏度、线性范围和稳定性。最后,探讨了Tween 20对三丙胺电化学行为的影响。结果 Tween 20浓度为0.1%时,对联吡啶钌电化学发光的增敏作用最佳。在此浓度下,联吡啶钌的检测灵敏度提高了100倍,在浓度为5×10-11~1×10-7mol/L范围内与电化学发光强度呈良好的线性关系,且Tween 20能促进三丙胺在电极表面的直接氧化并增强其氧化电流。结论 Tween 20对联吡啶钌的电化学发光具有较强的增敏作用。

Objective To improve the sensitivity of the Ru(bpy)2+3  electrochemiluminescence (ECL) detection, the sensitization of nonionic surfactant Tween 20 on the ECL of Ru (bpy)2+3 was studied. Methods The concentration of Tween 20 added was optimized firstly. In the optimum concentration of Tween 20 as 0.1%, the sensitivity, linear range and repeatability of Ru(bpy)2+3 were tested. Then, the effects of Tween 20 on the electrochemical behavior of tripropylamine were discussed.Results When the concentration of Tween 20 was 0.1%, the sensitization on the ECL was best. In this concentration, the sensitivity of Ru(bpy)2+3 increased 100 times, and there was a good linear relationship between the concentration of Ru(bpy)2+3 and ECL intensity in the range of 5×10-11 to 1×10-7mol/L. Moreover, Tween 20 could promote the direct oxidation of tripropylamine on the electrode surface and enhance the oxidation current. Conclusions Tween 20 has strong sensitization of on the ECL of Ru(bpy)2+3. 

参考文献:

[1]Liu JF, Cao WD, Yang XR,etal. Determination of diphenhydramine by capillary electro-phoresis with tris(2,2′- bipyridyl) ruthenium(II) electrochemiluminescence detection[J]. Talanta, 2003, 59(3):453-459.
[2]孙波,漆红兰, 凌晨, 等. 联吡啶钌电化学发光传感器测定海洛因[J]. 分析化学, 2009, 37(11):1601-1605.
 Sun Bo, Qi Honglan, Ling Cheng, et al. Sensitive Electrogenerated Chemiluminescence Sensor for Determination of Heroin[J]. Chinese Journal of Analytical Chemistry, 2009, 37(11):1601-1605.
[3]Costin JW, Barnett NW, Lewis SW. Deter-mination of proline in wine using flow injection analysis with tris(2,2′-bipyridyl)ruth-enium(II) chemiluminescence detection[J].Talanta, 2004, 64(4):894-898.
[4]Zhan W, Bard AJ. Electrogenerated Chemilu-minescence .83. Immunoassay of Human C-Reactive Protein by Using Ru(bpy)2+3-Encapsulated Liposomes as Labels[J]. Anal Chem,2007, 79(2):459-463.
[5]Miao WJ, Bard AJ. Electrogenerated chemi-luminescence.77.DNA hybridization detection at high amplification with [Ru(bpy)2+3]-containing microspheres[J]. Anal Chem,2004, 76(18):5379-5386.
[6]Dennany L, Forster RJ, Rusling JF. Simul-taneous direct electrochemiluminescence and catalytic voltammetry detection of DNA in ultrathin films[J]. J Am Chem Soc, 2003,125 (17):5213-5218.
[7]Guo GM, Chen QA, Chen X. Electrochemi-luminescence glucose biosensor based on glu-cose dehydrogenase functionalized Ru(bpy)2+3 doped silica nanoparticles[J]. Scl Chlna Chem, 2011, 54(11): 1777-1781.
[8]Jia TT, Cai ZM, Chen XM. et al. Electro-generated chemiluminescence ethanol bio-sensor based on alcohol dehydrogenase functionalized Ru(bpy)2+3 doped silica nano-particles [J]. Biosensors & Bioelectronics, 2009, 25(1):263-267.
[9]Liu XQ, Shi LH, Niu WX. et al. Environ-mentally Friendly and Highly Sensitive Ruthenium(II) Tris(2,2′-bipyridyl) Electroch-emiluminescent System Using 2-(Dibutyl-amino) ethanol as Co-Reactant [J]. Angew Chem Int Ed, 2007, 119(3): 425-428.
[10]杨洋, 孙世国, 刘凤玉, 等. 三联吡啶钌电化学发光机理及改善其强度的途径[J]. 化学通报, 2009, 72(9):768-775.
Yang Yang, Sun Shiguo, Liu Fengyu, et al. Mechanism of Ru(bpy)32+ electrochemiluminescence and effective methods for enhancing its intensity[J]. Chemistry, 2009, 72(9):768-775.
[11]Xu GB, Pang HL, Xu Bo.etal. Enhancing the electrochemiluminescence of tris(2,2′-bipyridyl) ruthenium (II) by ionic surfactants[J]. Analyst, 2005, 130(4), 541-544.
[12]Workman S, Richter MM. The Effects of Nonionic Surfactants on the Tris(2,2′-bipyridyl) ruthenium(II)-Tripropylamine Electrochemilum-inescence System[J]. Anal Chem, 2000, 72(22): 5556-5561.
[13]Factor B, Muegge B, Workman S,et al. Surfactant Chain Length Effects on the Light Emission of Tris(2,2′-bipyridyl)ruthenium(II)/ Tripropylamine Electrogenerated Chemilu-minescence[J]. Anal Chem, 2001, 73(19): 4621-4624.
[14]Noffsinger JB, Danielson ND. Generation of chemiluminescence upon reaction of aliphatic amines with tris(2,2′-bipyridine)ruthenium(III) [J]. Anal Chem, 1987, 59(6):865-868.
[15]Leland JK, Powell MJ. Electrogenerated Chemiluminescence: An Oxidative-Reduction Type ECL Reaction Sequence Using Tripropyl Amine[J]. J Electro-chem Soc, 1990, 137(10):3127-3131.
[16]Miao WJ, Choi JP, Bard AJ. Electrogenerated Chemiluminescence 69: The Tris(2,2′-bipy-ridine) ruthenium(II), (Ru(bpy)2+3)/Tri-n-pro-pylamine (TPrA) System Revisited-A New Route Involving TPrA·+ Cation Radicals[J]. J Am Chem Soc, 2002, 124(48): 14478-14485.

服务与反馈:
文章下载】【加入收藏
提示:您还未登录,请登录!点此登录
 
友情链接  
地址:北京安定门外安贞医院内北京生物医学工程编辑部
电话:010-64456508  传真:010-64456661
电子邮箱:llbl910219@126.com