Objective To evaluate the vascular interventional skill objectively by collecting the contact force between the instrument and the phantom during simulant invasive surgeries. Methods Firstly
a quantitative platform for interventional operation was constructed
which included a in?vitro aortic phantom
a mock circulation loop
visual and mechanical modules
as well as control terminals
capable of collecting mechanical data during the intervention process. Secondly
six experienced doctors and fifteen novices were selected as experimental subjects with different levels of intervention to complete the task of delivering medical catheters to the target vascular location of the aortic phantom. Two doctors and four novices were selected as the test group
and the rest data were selected as the training group. Finally
thirteen statistical features were extracted from the mechanical data
and the effective features were selected through nonparametric test and correlation analysis. The evaluation model was trained using the effective feature data of the training group. The test group was qualitatively classified based on support vector machine ( SVM) and quantitatively analyzed based on Mahalanobis distance (MD). Results There were significant differences in task time and mechanical data between doctors and novices. In the test group
the accuracy rate of qualitative classification was 90%. Quantitative analysis showed that doctors score significantly higher than novices ( 67?? 46 ± 12?? 92 vs 29?? 26 ± 16?? 50
P<0?? 001)
and the quantitative scores of experimenters showed an upward trend with the increase of intervention times. Conclusions The objective evaluation method based on mechanical parameters can provide good qualitative and quantitative evaluation results
and can be used as an auxiliary tool for the training of interventional doctors in the future.