Objective Pericardial effusion ( PE) refers to the excessive secretion of fluid in the pericardium caused by pericardial or systemic diseases. As a pathological manifestation
echocardiography is currently the most commonly used method for detecting pericardial effusion in clinical practice. However
this detection technique highly depends on the operator ’ s clinical experience. Therefore
this study develops a deep learning method for quantitatively measuring PE in echocardiograms
aiming to achieve automation of pericardial effusion measurement during echocardiographic examination. Methods Firstly
the residual network (ResNet) is used to classify the four detection views:the left ventricular short?axis view (SAX)
the right ventricular outflow tract view (RVOT)
the parasternal long?axis view of the left ventricle ( PLAX)
and the apical four?chamber view ( A4C). Then
VGG is incorporated into the Unet network
and transfer learning is utilized for the automatic segmentation of pericardial effusion. The segmentation network is evaluated using the Dice similarity coefficient
accuracy
and recall. Finally
the maximum inscribed measurement method is used to calculate the maximum depth of PE from the segmented labels. Results In the image classification module
the average accuracy for categorizing the four standard views is 0?? 84. For the automatic pericardial effusion ( PE ) segmentation module
the mean segmentation accuracy across test sets reach 0?? 82. Consistency analysis between the proposed automated measurement method and manual physician annotations yield an intraclass correlation coefficient ( ICC) of 0. 928 ( 95% CI:0?? 832 - 0?? 962)
demonstrating strong agreement. Conclusions This method exhibits robust performance in view classification
PE segmentation
and maximum depth quantification
offering a standardized and objective solution for future PE detection