Application of multimodal ultrasound technology in the clinical efficacy evaluation of neoadjuvant chemotherapy for breast cancer
|更新时间:2026-01-26
|
Application of multimodal ultrasound technology in the clinical efficacy evaluation of neoadjuvant chemotherapy for breast cancer
Vol. 44, Issue 6, (2025)
作者机构:
作者简介:
基金信息:
DOI:
CLC:R318;R445.1
Published:2025
稿件说明:
移动端阅览
郭强, 唐敏, 魏国李, et al. Application of multimodal ultrasound technology in the clinical efficacy evaluation of neoadjuvant chemotherapy for breast cancer[J]. 2025, 44(6).
DOI:
郭强, 唐敏, 魏国李, et al. Application of multimodal ultrasound technology in the clinical efficacy evaluation of neoadjuvant chemotherapy for breast cancer[J]. 2025, 44(6).DOI:
Application of multimodal ultrasound technology in the clinical efficacy evaluation of neoadjuvant chemotherapy for breast cancer
Objective To evaluate the clinical application value of dual?mode ultrasonography ( pulse Doppler + contrast?enhanced ultrasound ) in evaluating the efficacy of neoadjuvant chemotherapy for breast cancer. Methods A total of 128 female patients diagnosed with breast cancer after puncture biopsy admitted to Dazhou Central Hospital from May 2021 to May 2023 were selected as subjects in this study
all of whom received neoadjuvant chemotherapy (NAC) for breast cancer. According to the NAC results
all patients were divided into NAC effective group and NAC ineffective group
and the data of patients in the two groups were statistically analyzed before chemotherapy
after 2 cycles of chemotherapy
4 cycles and 6 cycles
mainly including the tumor size
boundary
capsule or not
internal echo
lobed or not
and sound halo recorded by conventional ultrasonography. The peak systolic flow velocity ( PSV)
end?diastolic flow velocity (EDV) and resistance index (RI) of the thickest and fastest nourishing artery in the same part of the mass were measured by pulsed Doppler ultrasound each time. The size of the blood perfusion area and the presence of perfusion defects were observed by contrast?enhanced ultrasound
and the time intensity curve (TIC) was used to analyze the arrival time (AT)
peak time ( TTP)
peak intensity ( PI)
and area under the curve ( AUC). Results Before the initiation of chemotherapy and during the second cycle
no statistically significant differences were observed in all pulse Doppler and contrast?enhanced ultrasound parameters between the effective and ineffective groups (P> 0.05). In the fourth cycle
statistically significant differences emerged in peak systolic velocity (PSV) and resistance index (RI) among pulse Doppler parameters
as well as perfusion index (PI) and area under the curve (AUC) among contrast?enhanced ultrasound parameters (P<0.05). However
no significant differences were noted in end?diastolic velocity (EDV)
size of the blood perfusion area
arrival time (AT)
or time to peak ( TTP ) ( P > 0.05). By the sixth cycle
all evaluated pulse Doppler and contrast?enhanced ultrasound parameters demonstrated statistically significant differences (P<0.05). During the second and fourth cycles
the diagnostic efficacy of either pulsed Doppler ultrasound or contrast?enhanced ultrasound alone for evaluating the therapeutic effects of neoadjuvant chemotherapy ( NAC) was relatively low ( AUC < 0.7). In contrast
by the sixth cycle
the diagnostic efficacy of both modalities significantly improved (AUC>0.7). When combining pulsed Doppler ultrasound with contrast?enhanced ultrasound for diagnosis
the diagnostic efficacy remained relatively low during the second cycle (AUC<0.7)
yet reached a satisfactory level during the fourth cycle (AUC>0.7). Furthermore
the diagnostic efficacy continued to improve during the sixth cycle (AUC> 0.7)
indicating an enhancement in the early diagnostic capability of the combined approach. During the intermediate phase of chemotherapy ( fourth cycle)
when the diagnostic efficacy of single modalities was still insufficient (AUC<0.7)
the combined diagnostic method was already capable of providing clinically valuable efficacy evaluations (AUC>0.7). This combined technology effectively overcame the limitations of individual modalities at specific time points or indicators
enabling more comprehensive and sensitive monitoring of therapeutic effects. Conclusions Dual?mode ultrasound technique is feasible and has certain clinical value in the diagnosis of neoadjuvant chemotherapy for breast cancer.