目的
2
探讨胚胎实验室应用基于电子标签的智能核对系统对工作效率及安全性的影响,明确其应用优势与后续改进方向,为完善胚胎实验室内部质量控制体系、提升质控水平提供支撑。
方法
2
备皿环节设电子标签组和手写标识组;冷冻载杆准备环节设电子标签组和手写标识组;冷冻核对环节设电子核对组和人工核对组;另根据电子标签批号分为批号1和批号2两组。本研究收集了2025年3月28日—4月26日各组别每次操作的耗时或标签起翘率数据。采用SPSS 23.0进行数据分析,计量资料以均数±标准差描述,组间比较采用
t
检验;计数资料以例数(百分比)[
n
(%)]描述,组间比较采用
χ
²检验。以
P
<
0.05为差异具有统计学意义,
P
<
0.001为差异具有极显著统计学意义。
结果
2
备皿环节:电子标签组平均耗时[(12.07±1.46) s]明显低于手写标识组[(24.13±2.28) s],差异极显著(
P
<
0.001);冷冻载杆准备环节:电子标签组平均耗时[(13.11±1.89) s]显著低于手写标识组[(23.10±2.73) s],两组差异达极显著水平(
P
<
0.001);冷冻核对环节:电子核对组平均耗时[(5.50±0.93) s]显著低于人工核对组[(11.38±2.07) s],差异极显著(
P
<
0.001)。电子标签未发生脱落现象(0/1 055)。进一步统计电子标签起翘情况,批号1标签组起翘率为5.61%(30/535),高于批号2标签组的4.81%(25/520),但差异无统计学意义(
P
>
0.05)。
结论
2
基于电子标签的智能核对系统的应用,不仅能显著提升胚胎实验室的工作效率、优化操作流程,更能为胚胎实验室内部质量控制工作的完善升级,提供新的改进方向。
Objective
2
To explore the impact of the application of electronic tags and intelligent verification systems in
in vitro
fertilization (IVF) laboratories on work efficiency and safety, clarify their application advantages and subsequent improvement directions, and provide support for improving the internal quality control system and enhancing the quality control level of embryo laboratories.
Methods
2
Dish preparation was divided into an electronic tag group and a manual group; cryo-straw preparation was categorized into an electronic tag group and a manual group; cryopreservation verification was separated into an electronic verification group and a manual verification group. Additionally, electronic tags were further classified into two groups of Batch1 and Batch2 based on batch numbers. The per-operation time of each group in different processes and the tag lifting incidence were collected from March 28 to April 26, 2025. Data analysis was performed using SPSS 23.0 software. Measurement data were presented as mean ± standard deviation and compared using the
t
-test. Count data were expressed as cases (percentages) [
n
(%)] and analyzed using the χ
2
test. A value of
P
<
0.05 was considered statistically significant, and
P
<
0.001 was considered extremely statistically significant.
Results
2
In dish preparation, the average time consumption of electronic tag group [(12.07±1.46) s] was shorter than that of manual group [(24.13±2.28) s], with an extremely significant difference (
P
<
0.001). In cryo-straw preparation, the average time consumption of electronic tag group [(13.11±1.89)s] was less than that of manual group [(23.10±2.73)s], and the difference between the two groups reached an extremely significant
level (
P
<
0.001). In cryopreservation verification, the average time consumption of electronic verification group [(5.50±0.93) s] was shorter than that of manual verification group [(11.38±2.07) s], with an extremely significant difference (
P
<
0.001). No detachment of electronic tags was observed (0/1 055). Further statistical analysis was conducted on the occurrence of tag lifting, and the proportion in Batch1 was 5.61% (30/535), which was higher than 4.81% (25/520) in Batch2, but the difference was not statistically significant (
P>
0.05).
Conclusions
2
The application of intelligent verification systems based on electronic tags can not only significantly improve the work efficiency of IVF laboratories and optimize operational processes, but also provide a new direction for the improvement and upgrading of their internal quality control.
Magli MC, Van den Abbeel E, Lundin K, et al. Revised guidelines for good practice in IVF laboratories[J]. Human Reproduction, 2008, 23(6): 1253-1262.
吴红萍, 刘平, 陈立雪, 等. 配子与胚胎实验室差错防范策略——“配子安全核查表”的建立与使用[J]. 中华生殖与避孕杂志, 2025, 45(4): 353-357.
Wu HP, Liu P, Chen LX, et al. Error prevention strategies in gamete and embryo laboratories: establishment and implementation of the “Gamete Safety Checklist”[J]. Chinese Journal of Reproduction and Contraception, 2025, 45(4): 353-357.
蔡令波, 黄洁, 刘嘉茵. 辅助生殖技术的安全核查管理与流程[J]. 中华生殖与避孕杂志, 2018, 38(8): 647-648.
Cai LB, Huang J, Liu JY. Management of safety verification and process of assisted reproductive technology[J]. Chinese Journal of Reproduction and Contraception, 2018, 38(8): 647-648.
Rasouli MA, Moutos CP, Phelps JY. Liability for embryo mix-ups in fertility practices in the USA[J]. Journal of Assisted Reproduction and Genetics, 2021, 38(5): 1101-1107.
Simana S, Ravitsky V, Cohen IG. The misplaced embryo: legal parenthood in ‘embryo mix-up’ cases[J]. Journal of Medical Ethics, 2023 52(4): 267-273.
Schulz I, Schulte J, Dipl-Med DW. Zygotic-splitting after in vitro fertilization and prenatal parenthood testing after suspected embryo mix-up—a case report[J]. International Journal o f Legal Medicine, 2024, 138(5): 2057-2064.
de los Santos MJ, Ruiz A. Protocols for tracking and witnessing samples and patients in assisted reproductive technology[J]. Fertility and Sterility, 2013, 100(6): 1499-1502.
黄国宁. 胚胎实验室全流程管理的核心监控指标[J]. 中华生殖与避孕杂志, 2024, 44(7): 686-690.
Huang GN. Key performance indicators for comprehensive process management in embryology laboratories[J]. Chinese Journal of Reproduction and Contraception, 2024, 44(7): 686-690.
Romanski PA, Thomas AM, Patel J, et al. Electronic whiteboard implementation as a quality management tool optimizes IVF laboratory standardization and improves clinical outcomes[J]. Journal of Assisted Reproduction and Genetics, 2021, 38(1): 203-210.
Sterckx J, Wouters K, Mateizel I, et al. Electronic witnessing in the medically assisted reproduction laboratory: insights and considerations after 10 years of use[J]. Human Reproduction, 2023, 38(8): 1529-1537.
李东英, 燕志光, 张春荣, 等. 辅助生殖中电子标签应用于患者身份信息核对及配子的标记识别[J]. 中华生殖与避孕杂志, 2018, 38(4): 329-332.
Li DY, Yan ZG, Zhang CR, et al. Use radio-frequency identification tags in assisted reproductive management to achieve more efficient and reliable identification of identity information[J]. Chinese Journal of Reproduction and Contraception, 2018, 38(4): 329-332.
Forte M, Faustini F, Maggiulli R, et al. Electronic witness system in IVF—patients perspective[J]. Journal of Assisted Reproduction and Genetics, 2016, 33(9): 1215-1222.
Jiang M, Guo L, Li S, et al. IVF laboratory management through workflow-based RFID tag witnessing and real-time information entry[J]. Reproductive Biology and Endocrinology, 2024, 22(1): 96.
Holmes R, Wirka KA, Catherino AB, et al. Comparison of electronic versus manual witnessing of procedures within the in vitro fertilization laboratory: impact on timing and efficiency[J]. Fertility and Sterility Reports, 2021, 2(2): 181-188.
Rienzi L, Bariani F, Dalla Zorza M, et al. Failure mode and effects analysis of witnessing protocols for ensuring traceability during IVF[J]. Reproductive BioMedicine Online, 2015, 31(4): 516-522.
Cimadomo D, Ubaldi FM, Capalbo A, et al. Failure mode and effects analysis of witnessing protocols for ensuring traceability during PGD/PGS cycles[J]. Reproductive BioMedicine Online, 2016, 33(3): 360-369.
鲍胜文, 方拥军, 肖小兵, 等. RFID技术在医疗设备管理系统中的研究与应用[J]. 电子产品世界, 2022, 29(3): 43-46.
Bao SW, Fang YJ, Xiao XB, et al. Research and application of RFID technology in medical equipment management system[J]. Electronic Engineering & Product World, 2022, 29(3): 43-46.
Gupta S, Fauzdar A, Singh VJ, et al. A preliminary experience of integration of an electronic witness system, its validation, efficacy on lab performance, and staff satisfaction assessment in a busy Indian in vitro fertilization laboratory[J]. Journal of Human Reproductive Sciences, 2020, 13(4): 333-339.