1.中国食品药品检定研究院(北京 102629)
2.中国药科大学(南京 211198)
韩倩倩。E-mail:hanqianqian2005@163.com
收稿:2025-11-17,
修回:2026-02-06,
网络首发:2026-08-17,
纸质出版:2026-08-20
移动端阅览
吴世泽,宋卓钰,韩倩倩.脂肪族聚酯医用材料及其体内降解机制研究进展[J].北京生物医学工程,2026,45(4):433-438.
WU Shize,SONG Zhuoyu,HAN Qianqian.Research progress on aliphatic polyester medical materials and their in vivo degradation mechanisms[J].Beijing Biomedical Engineering,2026,45(4):433-438.
吴世泽,宋卓钰,韩倩倩.脂肪族聚酯医用材料及其体内降解机制研究进展[J].北京生物医学工程,2026,45(4):433-438. DOI: 10.3969/j.issn.1002-3208.2026.04.015.
WU Shize,SONG Zhuoyu,HAN Qianqian.Research progress on aliphatic polyester medical materials and their in vivo degradation mechanisms[J].Beijing Biomedical Engineering,2026,45(4):433-438. DOI: 10.3969/j.issn.1002-3208.2026.04.015.
作为一类重要的生物可降解高分子材料,脂肪族聚酯凭借其良好的生物相容性在医用领域中发挥着关键作用。本文系统介绍了聚乳酸(polylactic acid, PLA)、聚己内酯(polycaprolactone, PCL)、聚乙醇酸(polyglycolic acid, PGA)和聚乳酸-羟基乙酸共聚物(polylactic-co-glycolic acid, PLGA)这几种常见脂肪族聚酯的基本特性与应用现状。重点探讨脂肪族聚酯在复杂生理环境中的多种降解途径。其体内降解是一个受多重机制协同作用的复杂过程,主要包括以“本体侵蚀”或“表面侵蚀”为主导的水解降解、特定酶参与的酶促降解以及活性氧引发的氧化降解。聚酯的降解行为不仅与材料本身的化学结构、结晶度、分子量等本征因素密切相关,也受所处机体微环境影响,包括体液的pH值、酶活性、ROS水平以及力学应力。其降解产生的酸性单体等产物通常可通过三羧酸循环、β-氧化等途径被机体代谢,但局部过量积累可能引发炎症反应,部分中间产物的长期代谢安全性仍需充分验证。针对目前脂肪族聚酯在体内复杂环境中的交互作用研究不足、降解产物的代谢安全性验证不充分等问题,本文对未来研究方向提出展望及建议,以期为该类材料的合理设计与临床应用提供参考。
As an important class of biodegradable polymers, aliphatic polyesters play a crucial role in the medical field due to their excellent biocompatibility. This paper systematically introduces the basic characteristics and current applications of several common aliphatic polyesters, including polylactic acid (PLA), polycaprolactone (PCL), polyglycolic acid (PGA), and polylactic-co-glycolic acid (PLGA). The focus is on exploring the various degradation pathways of aliphatic polyesters in complex physiological environments. Their
in vivo
degradation is a complex process involving multiple synergistic mechanisms, primarily including hydrolytic degradation dominated by “bulk erosion” or “surface erosion”, enzyme-catalyzed degradation involving specific enzymes, and oxidative degradation triggered by reactive oxygen species (ROS). The degradation behavior of polyesters is not only closely related to their intrinsic factors such as chemical structure, crystallinity, and molecular weight but also influenced by the microenvironment within the host organism, including pH of body fluids, enzyme activity, R
OS levels, and mechanical stress. The acidic monomers and other products generated during degradation can typically be metabolized
via
pathways such as the tricarboxylic acid cycle and β-oxidation. However, excessive local accumulation may induce inflammatory responses, and the long-term metabolic safety of certain intermediate products still requires thorough validation. Addressing current issues such as insufficient research on the interactions of aliphatic polyesters within complex biological environments and the inadequate verification of the metabolic safety of degradation products, this article offers prospects and suggestions for future research directions, aiming to provide references for the rational design and clinical application of these materials.
Zhang Q, Song M, Xu Y, et al. Bio-based polyesters: recent progress and future prospects[J]. Progress in Polymer Science, 2021, 120: 101430.
Darie-Nită RN, Râpă M, Frąckowiak S. Special features of polyester-based materials for medical applications[J]. Polymers, 2022, 14(5): 951.
Manavitehrani I, Fathi A, Badr H, et al. Biomedical applications of biodegradable polyesters[J]. Polymers, 2016, 8(1): 20.
Majola A, Vainionpää S, Vihtonen K, et al. Absorption, biocompatibility, and fixation properties of polylactic acid in bone tissue: an experimental study in rats[J]. Clinical Orthopaedics and Related Research, 1991(268): 260-269.
邢璐, 李博宁, 肖本好, 等. 医用聚乳酸材料性能及加工方法研究进展[J]. 高分子材料科学与工程, 2023, 39(6): 167-174.
Xing L, Li BN, Xiao BH,et al. Progress of properties and processing methods of medical poly (lactic acid) materials[J]. Polymer Materials Science and Engineering, 2023, 39(6): 167-174.
Lin CY, Lin JY, Yang DY, et al. Efficacy and safety of poly-D, L-lactic acid microspheres as subdermal fillers in animals[J]. Plastic and Aesthetic Research, 2019, 6: 16.
Liu S, Wu G, Zhang X, et al. Preparation and properties of poly (lactic acid)(PLA) suture loaded with PLA microspheres enclosed drugs (PM-Ds)[J]. The Journal of The Textile Institute, 2019, 110(11): 1596-1605.
Wang C, Wang H, Chen Q, et al. Polylactic acid scaffold with directional porous structure for large-segment bone repair[J]. International Journal of Biological Macromolecules, 2022, 216: 810-819.
Li G, Zhao M, Xu F, et al. Synthesis and biological application of polylactic acid[J]. Molecules, 2020, 25(21): 5023.
Bartnikowski M, Dargaville TR, Ivanovski S, et al. Degradation mechanisms of polycaprolactone in the context of chemistry, geometry and environment[J]. Progress in Polymer Science, 2019, 96: 1-20.
Malikmammadov E, Tanir TE, Kiziltay A, et al. PCL and PCL-based materials in biomedical applications[J]. Journal of Biomaterials Science, Polymer Edition, 2018, 29(7-9): 863-893.
Dias JR, Sousa A, Augusto A, et al. Electrospun polycaprolactone (PCL) degrada tion: an in vitro and in vivo study[J]. Polymers, 2022, 14(16): 3397.
Astuti SH, Rahma WA, Budianto E. Biodegradable Microcapsules from D, L-PLA/PCL as Controlled Nifedipine Drug Delivery Carrier[J]. Macromolecular Symposia, 2020, 391(1): 1900132.
Hakim SL, Kusumasari FC, Budianto E. Optimization of biodegradable PLA/PCL microspheres preparation as controlled drug delivery carrier[J]. Materials Today: Proceedings, 2020, 22: 306-313.
Siddiqui N, Asawa S, Birru B, et al. PCL-based composite scaffold matrices for tissue engineering applications[J]. Molecular Biotechnology, 2018, 60(7): 506-532.
Edlund U, Albertsson AC. Degradable polymer microspheres for controlled drug delivery[M]//Degradable aliphatic polyesters. Berlin, Heidelberg: Springer Berlin Heidelberg, 2002: 67-112.
Budak K, Sogut O, Aydemir Sezer U. A review on synthesis and biomedical applications of polyglycolic acid[J]. Journal of Polymer Research, 2020, 27(8): 208.
Sato H, Miyada M, Yamamoto S, et al. C-H⋯ O (ether) hydrogen bonding along the (110) direction in polyglycolic acid studied by infrared spectroscopy, wide-angle X-ray diffraction, quantum chemical calculations and natural bond o rbital calculations[J]. RSC Advances, 2016, 6: 16817-16823.
Little A, Ma S, Haddleton DM, et al. Synthesis and Characterization of High Glycolic Acid Content Poly (glycolic acid-co-butylene adipate-co-butylene terephthalate) and Poly (glycolic acid-co-butylene succinate) Copolymers with Improved Elasticity[J]. ACS Omega, 2023, 8(41): 38658-38667.
Sy J, Xu X, Marie Lipski A, et al. Degradation behavior of novel poly(α-hydroxy acid)-derived polyesters[J]. MRS Online Proceedings Library, 2004, 823(1): W11.10.
Dardik H, Dardik I, Laufman H. Clinical use of polyglycolic acid polymer as a new absorbable synthetic suture[J]. The American Journal of Surgery, 1971, 121: 656-660.
Zhang Y, Jian Y, Jiang X, et al. Stepwise degradable PGA-SF core-shell electrospinning scaffold with superior tenacity in wetting regime for promoting bone regeneration [J]. Materials Today Bio, 2024, 26: 101023.
Sekiya N, Ichioka S, Terada D, et al. Efficacy of a poly glycolic acid (PGA)/collagen composite nanofibre scaffold on cell migration and neovascularisation in vivo skin defect model[J]. Journal of Plastic Surgery and Hand Surgery, 2013, 47(6): 498-502.
Samanta D, Koithan JA, Muliana AH, et al. Effect of mechanical loading on PLGA biodegradation[J]. Polymer Degradation and Stability, 2025, 240: 111485.
Therin M, Christel P, Li S, et al. In vivo degradation of massive poly (α-hydroxy acids): validation of in vitro findings[J]. Biomaterials, 1992, 13(9): 594-600.
Ji YB, Lee S, Ju HJ, et al. Preparation and evaluation of injectable microsphere formulation for longer sustained release of donepezil[J]. Journal of Controlled Release, 2023, 356: 43-58.
Rosato A, Romano A, Totaro G, et al. Enzymatic degradation of the most common aliphatic bio-polyesters and evaluation of the mechanisms involved: an extended study[J]. Polymers, 2022, 14: 1850.
Mallepally RR, Smirnova I, Arlt W, et al. Enzymatic degradation of hyperbranched polyesters[J]. Journal of Applied Polymer Science, 2009, 112(4): 1873-1881.
Tsuji H, Kidokoro Y, Mochizuki M. Enzymatic degradation of biodegradable polyester composites of poly (L‐lactic acid) and poly (ε‐caprolactone)[J]. Macromolecular Materials and Engineering, 2006, 291: 1245-1254.
Chen Z, Ding D, Yu T, et al. Enzymatic degradation behaviors and kinetics of bio-degradable jute/poly (lactic acid)(PLA) composites[J]. Composites Communications, 2022, 33: 101227.
Sukanya VS, Mohanan PV. Degradation of Poly (ε- caprolactone) and bio-interactions with mouse bone marrow mesenchymal stem cells[J]. Colloids and Surfaces B: Biointerfaces, 2018, 163: 107-118.
Gong P, Ren L, Gao X, et al. A novel barrier membrane with long-term ROS scavenging function for complete prevention of postoperative adhesion[J]. Materials & Design, 2024, 238: 112691.
Fang D, Qin Z, Zheng L, et al. Ros-responsive nanocomposite scaffolds for sustained releasing puerarin to achieve chondroprotection in OA rats[J]. Materials & Design, 2023, 233: 112214.
Zhang ZY, Zheng WZ, Zhen ZC, et al. In vivo and in vitro degradation and biological toxicity studies of polyesters with varying degradation rates[J]. Journal of Hazardous Materials, 2025, 492: 138196.
Taylor MS, Daniels AU, Andriano KP, et al. Six bioabsorbable polymers: in vitro acute toxicity of accumulated degradation products[J]. Journal of Applied Biomaterials, 1994, 5(2): 151-157.
Ermolenko YV, Semyonkin AS, Ulianova YV, et al. Role of hydrolytic degradation of polylactide drug carriers in developing micro-and nanoscale polylactide-based drug dosage forms[J]. Russian Chemical Bulletin, 2020, 69(8): 1416-1427.
Bogdanova A, Pavlova E, Polyanskaya A, et al. Acceleration of electrospun PLA degradation by addition of gelatin[J]. International Journal of Molecular Sciences, 2023, 24: 3535.
Yoon SK, Chung DJ. In vivo degradation studies of PGA-PLA block copolymer and their histochemical analysis for spinal-fixing application[J]. Polymers, 2022, 14: 3322.
Mayer JB, Patil SM, Shin SH, et al. Internal water-induced acceleration, chemical pathways, and contributing factors in the degradation of poly (lactic-co-glycolic acid)(PLGA) microparticles and devices[J]. ACS Biomaterials Science & Engineering, 2025, 11(7): 3932-3948.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621